SRD-S-124D – Relay

Part Number : SRD-S-124D

Function : Relay

Manufactures : Sanyou

Images :

1 page
SRD-S-124D image

2 page
pinout

Description :

SANYOU RELAYS Relays for advanced technology Miniature Power Relay SRD-Series Contact Capacity Features ● High contact capability: 12A switching capability. ● Low coil power consumption, low price. ● Microminiature relay, standard PCB terminal. Safety Approval UL,C-UL File No.:E190598 TUV File No.:R50142424 CQC File No.:CQC02001002126 VDE File No.: 40034479 Model Nominal switching capacity (res. load) Max. switching current Max. switching voltage Max. switching power SRD -DM 10A 277 VAC 15A 277 VAC 2,77 0VA SRD -D & SRD-DB 7A 250VAC 12A 250VAC 1,750VA Charateristic Data Contact material Initial contact resistance (at 6VDC 1A) Operate time (at nominal volt.) Release time (at nominal volt.) Initial insulation resistance Initial dielectric strength Vibration resistance Shock resistance Endurance (operations) Ambient temperature Unit weight Silver alloy 100mΩ Max. 8msec. Max. 5msec. Max. 100MΩ Min.(DC500V) Between open contacts: AC750V,50/60Hz 1 M i n . Between coil and contact:AC1,500V,50/60Hz 1 M i n . Functional Destructive 10~55Hz at double amplitude of 1.5 mm 10~55Hz at double amplitude of 1.5 mm Functional 10G Min. Destructive Mechanical (at 10,800 ops./h) 100G Min. 10,000,000 cycles Electrical (at 1,800 ops./h) 100,000 cycles -40℃~+105℃ (no condensation) Approx. 8.5 g C o i l D a t a (at 20℃) Nominal voltage (VDC) 3 5 6 9 12 15 18 24 48 60 Nominal operating current ±10% (mA) 120.00 71.42 60.00 40.00 30.00 24.00 20.00 15.00 7.50 6.00 Coil resistance ±10% (Ω) 25 70 100 225 400 625 900 1,600 6,400 10,000 Max. allowable voltage 130 % of nominal voltage Pick-up voltage (Max.) 75 % of nominal voltage Drop-out voltage (Min.) Nominal operating power 5 % of nominal voltage 0.36W 1/3 Safety Approval Ratings SRD Approval CQC TUV VDE UL/CUL File No. CQC02001002126 R50142424 40034479 E190598 7A 250VAC Approved ratings 5A 240VAC 10A 250VAC (Form A & Form C NO) 7A 250VAC 7A 28VDC 10A 250VAC (Form A) Contact 2(Form C)or blank(Form A or Form B): 12A 125VAC,Resistive,NO&NC Contact 2 or blank: 10A 250VAC(Form C,NO) 7A 250VAC(Form C,NO) 6A 250VAC(Form C,NC) Contact 2 or blank: 10A 250VAC(Form A) 7A 250VAC(Form A) 15A 125VAC,Resistive,NO 10A 250VAC,Resistive,NO 7A 250VAC,General use,NO&NC 3A 125VAC,General Use,NO&NC 10A/6A 250VAC,General use,NO/NC 10A/6A 125VAC,General use,NO/NC 10A/6A 28VDC,General use,NO/NC Contact 3: 10A 250VAC(Form C,NO) 7A 250VAC(Form C,NO) 6A 250VAC(Form C,NC) 1/3HP 250VAC,NO&NC FLA 5A, LRA 10A, 120/ 240VAC, NO Pilot Duty:240VA,240VAC TV-3,120VAC,NO Contact 3: 10A 250VAC(Form A) 7A 250VAC(Form A) TV-5,120VAC,NO Contact 2(Form A or Form B)or blank(Form C): 12A/15A 125VAC,Resistive&General use,NO 10A 250VAC/28VDC,Resistive&General use,NO 1/3HP 250VAC,NO FLA 5A, LRA 10A, 120/ 240VAC, NO TV-3,120VAC,NO Contact 1 or 3: 12A/15A 125VAC,Resistive&General use,NO 10A 250VAC/28VDC,Resistive&General use,NO 1/3HP […]

3 page
image

SRD-S-124D Datasheet


This entry was posted in Uncategorized. Bookmark the permalink.