Part Number: RTM875N-397
Function: AC Performance Measurement Report
Manufacturer: Realtek Semiconductor
Images:
Description
RTM875N-397 is AC Performance Measurement Report.
Measurement Equipment :
Clock Rise Time / Fall Time Are Measured by Tektronix® 6804B with Single-ended Probe
1. Mainframe with 8.0GHz Bandwidth
2. Mainframe with 20GS/s Sampling Rate
3. P7240 Active Probe with 4.0GHz Bandwidth (input: 1.0pF / 20K-ohm)
Clock Jitter & Duty Cycle Are Measured by Tektronix® 6804B with Differential Probe
4. P7330 Differential Active Probe with 3.5GHz Bandwidth (input: 0.5pF / 100K-ohm)
5. Tektronix® Jitter Analysis 3® Jitter Measurement Software
Measurement Environment:
1. Test board
Measurement Item:
Differential Clock
1. Slew_Rise & Slew_Fall
2. Vcross & ΔVcross
3. Cycle to Cycle jitter
4. Vmax & Vmin
5. Duty Cycle
Single-end Clock
1. Slew_Rise & Slew_Fall
2. Duty Cycle
3. Cycle to Cycle jitter
Measurement Summary:
1. From the measurement shown as follows, RTM875N-397 works good and meets all CLK Spec.